Circuit Breaker Timer Test

It is also evident that when testing circuit breakers with timer as they are usually installed in an open air environment the testing conditions are unfavorable.
Circuit breaker timer test. The cbt 1201 circuit breaker timer unit incorporates a built in timer which captures trip close and bounce times. Very interesting are also new conceptions for testing of circuit breakers based on analysis of mechanical vibration signal 2. Field portable instruments with standalone or pc controlled functionality allow performing various tests during circuit breaker manufacturing commissioning and maintenance stages. With single instrument one can measure making breaking time of r y b arm of a breaker at a time.
A circuit breaker timing test is the process of measuring the mechanical operating times with the goal of verifying analyzing and validating the correct function of the circuit breaker. Vlsi digital circuit breaker timer cbt is in lcd display type. These circuit breaker testers are covered by united states patent number 9086447. The doble tdr900 is your entry level portable circuit breaker test set.
Use the tdr900 to verify control circuit check motion of moving parts validate time of operation and. The types of timer circuit breaker on the market that have manual control are very difficult to configure and testing a circuit breaker using them is a very slow process. It is used for substation breaker time measurement i. Circuit breaker timer incorporates digital timer 120vac 125vdc power supply for charging spring charged breakers outside cubicle switching to trip and close the breaker under test and includes unique cable sets which significantly simplify and speed connections to the breaker.
About circuit breaker analyzers timers cat circuit breaker analyzers and timers are advanced standalone or a pc controlled instruments for circuit breaker maintenance. About circuit breaker test equipment dv power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers. Typical application areas of cat instruments are medium and high voltage substations at electric power generation transmission and factories of switchgear. How to test a circuit breaker of this type depends on its maximum rated current the trip protection settings and the inverse curve types which will define the overload and short circuit trip pickup levels and time delays.
It operates and records a circuit breaker s contact timing motion velocity main contact engagement synchronization trip and close coil initiation and currents. Second generation testing methods based on digital timers with time pulse conversion e g. Circuit breaker timer produced by vanguard instruments company 1 began about 1988 year and are continued until today.