In electrical installations using the smallest possible conductor size that gets the job done saves money especially in larger projects with thousands of feet of wiring.
Circuit breaker ratings pec. Circuit breakers are designed to carry 100 of their rated current while the nec dictates an 80 application. Why limit circuit breaker rating based on conductor size. Where the rating of cooking appliances falls under both column a and column b the demand factors for each column shall be applied to the appliances for that column and the results added together. This rule states that an ocpd can be loaded to only 80 of its rating for continuous loads.
The short time rating of a circuit breaker ratings depends upon its ability to withstand a the electromagnetic force effects and b the temperature rise. Circuit breakers have an interrupting rating of 5 000a unless marked otherwise. Circuit breakers must be capable of being opened and closed by hand. Every circuit breaker having an interrupting rating other than 5000 amperes shall have its interrupting rating shown on the circuit breaker.
Circuit breaker ratings the rating of the circuit breaker is given on the duties that are performed by it. Circuit breakers rated at 100 amperes or less and 600 volts or less shall have the ampere rating molded stamped etched or similarly marked into their handles or escutcheon areas. Remember that 80 is the inverse of 125 0 80 1 divided by 1 25 and as such the rules are indeed identical in. The oil circuit breakers have a specified limit of 3 seconds when the ratio of symmetrical breaking current to the rated normal current does not exceed 40.
Miniature circuit breakers which in the uk have been manufactured since 1965 to. Non manual means of operating a circuit breaker such as electrical shunt trip or pneumatic operation are permitted if the circuit breaker can also be manually operated 240 80. Hence short circuit breaking capacity or short circuit breaking current of circuit breaker is defined as maximum current can flow through the breaker from time of occurring short circuit to the time of clearing the short circuit without any permanent damage in the cb. Maximum loading of any circuit breaker is 80 of rating for non motor loads with exceptions as noted below.
Circuit breaker size 2. Table 2 load maximum circuit breaker size of current resistance loads heat stoves toasters water heater 125. It shall be permissible to calculate the branch circuit load for one range in accordance with table 2 20 3 16. During short circuit the cb is not only subjected to thermal.
By limiting how small a conductor can be for a specific circuit breaker size the nec grants a degree of protection. Higher short circuit capacities up to 25ka are. The manufacturer must however declare the short circuit capacity of the products at specified power factors of test circuit. The value of short circuit breaking current is expressed in rms.
Apart from the normal working of circuit breakers the circuit breaker is required to perform following three major duties.